Here on the left side , when water comes in the system it forms a turbulence and the particles heavier than water descent into secret sand tank.
Sand tank is formed by two conical sections
NOTE : By switching bottom release valve secret sand tank must be emptied erIodically ( only within 6 - 8 seconds ) while the system is operating.
Hydrocyclone : Thıs ıs the fılter whıch separates partıcles heavıer than water. ıt ıs not recommended to use ıt alone ın the ırrıgatıon system. Because ıt can not separate lıght partıcles floatıng ın the water so thıs can cause blockıngs ın the system. a fılter must be ınstalled on the outlet ofhydrocyclone
WATER PERMEABILITY AND HEAD LOSS VALUES FOR SILT FILTER
| 2" | 2,5" | 3" | 4" | |
| 1 atm (Bar) | 9,83 ton/h | 14,2 ton/h | 14,7 ton/h | 19,6 ton/h |
| 2 atm (Bar) | 19,6 ton/h | 28,2 ton/h | 29,4 ton/h | 39,4 ton/h |
| 3 atm (Bar) | 29,4 ton/h | 42,4 ton/h | 44 ton/h | 57,6 ton/h |
| 4 atm (Bar) | 39,2 ton/h | 56,4 ton/h | 56 ton/h | 77,6 ton/h |
| 5 atm (Bar) | 49 ton/h | 70,5 ton/h | 70 ton/h | 95 ton/h |
| 6 atm (Bar) | 59 ton/h | 85 ton/h | 88,5 ton/h | 118ton/h |
| 2" | 2,5" | 3" | 4" | |||||
| 1 atm (Bar) | 0,7m | 0,07atm | 0,98m | 0,1atm | 1,3m | 0,13atm | 1,36m | 0,14atm |
| 2 atm (Bar) | 1,4m | 0,14atm | 1,96m | 0,2atm | 2,6m | 0,26atm | 2,72m | 0,27atm |
| 3 atm (Bar) | 2,1m | 0,21atm | 2,94m | 0,29atm | 3,9m | 0,39atm | 4,08m | 0,4atm |
| 4 atm (Bar) | 2,8m | 0,28atm | 3,92m | 0,39atm | 5,2m | 0,52atm | 5,44m | 0,55atm |
| 5 atm (Bar) | 3,5m | 0,35atm | 4,88m | 0,5atm | 6,5m | 0,65atm | 6,8m | 6,8atm |
| 6 atm (Bar) | 4,2m | 0,42atm | 5,9m | 0,6atm | 7,8m | 0,78atm | 8,2m | 0,82atm |